A: UPS battery commonly used types of factors that affect battery life, different kinds of advantages and disadvantages of the hp probook 4510s battery, hp probook 4710s battery:
The battery in the UPS application there are three: including open liquid lead acid batteries, maintenance-free batteries, nickel cadmium batteries. The UPS manufacturers are generally maintenance-free battery with battery, following the main battery so as not to introduce three types of battery maintenance features:
1: Open the liquid lead-acid batteries: These batteries can be classified according to structure 8-10 years ,15-20 two-year life. Because the battery will produce corrosive sulfuric acid electrolyte gas, such batteries must be installed in the ventilation and the room away from the sophisticated electronic equipment, and battery room should be corrosion resistant ceramic tile laying.
Reasons due to evaporation, the proportion of open cells to be regularly measured, acid water. The battery can tolerate high temperature and pressure and deep discharge. Smoking and use the battery room should open the battery holder.
The battery charge does not transport, and therefore must charge at the scene after the initial charging installation normally takes 55-90 hours. Each section of the normal voltage of 2V, initial charging voltage is 2.6-2.7v.
2: maintenance-free toshiba pa3820u-1brs battery, toshiba pa3821u-1brs battery: also known as VRLA batteries, in the use and maintenance must follow the following principles:
a: sealed battery can allow the operating range of 15 degrees -50 degrees, 5 degrees -35 degrees, but the use of extended battery life. Minus 15 degrees in the following chemical composition will change the battery can not charge. 20 degrees to 25 degrees in the range of use to a maximum of life. Batteries at low temperature operation will be long-lived but low capacity, high-temperature operation at a higher capacity but will be short-lived.
b: the relationship between battery life and temperature can refer to the following rules, after the temperature exceeds 25 degrees Celsius, 8.3 degrees per high battery life will be reduced by half.
c: the design of maintenance-free battery float voltage to 2.3V / section. 12V battery is 13.8V. CSB recommended that each company section 2.25-2.3V. In the case of 120 cells in series, the temperature is above 25 degrees Celsius, the temperature is increased float voltage should be reduced once 3MV. The same temperature is increased by less than once in order to avoid charging voltage should be increased 3MV. Discharge termination voltage at full load (<30 minutes) to 1.67V under each section. In the case of the low discharge rate (low current discharge time) increased to 1.7V-1.8V to each section, APC SYMMETRA can adjust the charge voltage according to load.
d: after discharge hp pavilion dv6000 battery, hp pavilion dv9000 battery within 72 hours if the battery does not recharge. Sulfate plates will be attached to the insulation charging, and damage the battery.
e: float or are charging the battery when the gas inside the battery into water electrolysis at the negative plate, so as to maintain the battery capacity and do not need additional water. However, the corrosion of the battery plate will reduce the battery capacity.
f: battery separators life in the environment only when the temperature is 30-40 degrees 5-6 months. Prolonged storage of the battery must be recharged every 6 months time. Batteries should be stored in a dry cool environment. Environment at 20 degrees the battery maintenance 3-4% per month self-discharge rate and temperature changes.
g: maintenance-free batteries are equipped with safety valve, when the battery internal pressure increases to a certain extent can be automatically excluded from the excess gas valve, safety valve in the internal air pressure is restored automatically restored.
h: battery cycle life (charge and discharge cycles life) depends on the discharge rate, discharge depth, and recovery of the charge by means of which the most important factor is the depth of discharge. In the discharge rate and time certain, the more shallow depth of discharge, the longer the battery cycle life dell studio xps 1645 battery, dell studio xps 1647 battery. Maintenance-free battery at 25 degrees under 100% deep discharge cycle life of about 200 times.
i: battery life is reached when the capacity fade performance of the internal short circuit, shell deformation, plate corrosion, open circuit voltage decreases.
j: IEEE defined as the capacity of the battery end of life less than 80% of the nominal capacity of AH. Nominal capacity and the actual backup time non-linear relationship, the corresponding reduction of 20% reserve capacity will reduce a lot of time. Some UPS manufacturers defined as the capacity of the battery end of life reduced to a nominal capacity of 50-60%.
k: the absolute prohibition of different sizes and different manufacturers of batteries together, otherwise it will reduce battery life.
l: If the two batteries in parallel, should ensure that the battery connection, the same bus impedance.
m: maintenance-free battery means you can not add liquid, but regular checks whether the shell cracks, leaks and other electrolytes is still necessary.
3: Ni-Cr Battery: This battery is different from the lead-acid batteries produce hydrogen and oxygen during electrolysis without corrosive gas, which can be installed next to the electronic device. Water consumption and small, generally do not need maintenance. Normal life span of 20-25 years. Expensive than the previously mentioned battery. Initial installation costs about three times the lead-acid batteries. And high ambient temperature will not affect battery life, it will not be sony vgp-bps15 battery, sony vgp-bpl15 battery affected by environmental temperature is low battery capacity. Voltage of each section typically 1.2V, UPS batteries need to design because of application of such a high charger voltage.
II: advantages and disadvantages:
An open lead-acid batteries:
Advantages: less investment, maintenance-free battery life than the long, low temperature requirements.
Disadvantages: maintenance of a more complex one that requires a special battery rooms, corrosive gas emissions must be on-site 50-90 hours of initial charging, need someone to maintain.
2: maintenance-free battery:
Advantages: no added liquid such as maintenance, transport in the fully charged state, no hand maintenance.
Disadvantages: not timely recovery of the charge will damage the battery, more sensitive to temperature, shorter life than lead-acid batteries expensive.
3: nickel cadmium batteries:
Advantages: low maintenance requirements, longer life expectancy, is not sensitive to temperature, no harmful gas emissions.
Disadvantages: the three most expensive batteries.
C: UPS battery commonly hp pavilion dm3 battery, hp pavilion dm4 battery used in
Most use the computer center are generally maintenance-free batteries, maintenance more convenient, but also in need of the following:
1: to discharge every three to four months time, to prevent the electrode oxidation.
2: The ambient temperature should be maintained at 20-25 degrees.
3: The connection can not be too tight and too loose, need regular inspection.
4: After three years, the need for timely check and replace.